EDIT

                                                                                
----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
EDIT                    3.5                 200.                                
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
1-6     A6        EDIT   - Specifies editing multiplier                         
                           and initial RMS value.                               
                                                                                
7       I1        Special editing switch.                        0              
                                                                                
                    = 0 Normal editing performed.                               
                    = 1 Perform local pass editing on                           
                      1st iteration.                                            
                    = 2 Perform local pass editing on                           
                      all iterations.                                           
                                                                                
25-44   D20.8     Editing multiplier. This number remains        3.5            
                  constant for all iterations in the arc.                       
                                                                                
45-59   D15.3     Editing RMS. Initial RMS value used for        200.           
                  iteration number 1. Subsequent iterations                     
                  use the RMS from the previous iteration.                      
                                                                                
60-72   D13.1     Electronic bias edit level.                Value in cols.     
                                                             25-44 times value  
                                                             in cols. 45-59.    
                                                                                
73-80   D8.2      Arc convergence criteria.                      .02            
                                                                                
                                                                                
  NOTES:                                                                        
     [1] The editing level for each iteration is determined as follows:         
                                                                                
              Edit level = Edit multiplier * Edit RMS                           
                                                                                
     [2] The "ratio to sigma" for each observation is compared to this edit     
         level and "ratio to sigmas" greater than the edit level are            
         eliminated from the current iterations solution.                       
                                                                                
     [3] The electronic bias edit level defaults to the same edit level as      
         described above. (edit multiplier * edit RMS)

JAN 1992

9201.0

ARC SET - Option Cards

EDIT (cont)

                                                                                
                                                                                
  NOTES:  (continued)                                                           
                                                                                
      [4] Time periods may be specified only for the highest order              
          coefficients                                                          
                                                                                
      [5] Convergence on first iteration                                        
          GEODYN II will converge on the first inner iteration if the           
          RMS on the EDIT card is within 2% of the first iteration RMS          
                                                                                
      [6] E-bias Edit level                                                     
          For E-bias editing the E-bias edit level is given by default          
          as the edit multiplier * RMS from the EDIT card. If the               
          "electronic bias edit level" from columns 60-72 of the EDIT           
          card is non zero, then the value from  column 60-72 is used as        
          the edit level (Not the value in column 60-72 times anything else)    
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
IF CARD OMITTED: The default edit level of 700 (3.5*200) is used.

JUNE 1991

9106.0

ARC SET - Option Cards



Patrick Dahiroc