----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
EDIT 3.5 200.
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
COLUMNS FORMAT DESCRIPTION DEFAULT VALUE & UNITS
1-6 A6 EDIT - Specifies editing multiplier
and initial RMS value.
7 I1 Special editing switch. 0
= 0 Normal editing performed.
= 1 Perform local pass editing on
1st iteration.
= 2 Perform local pass editing on
all iterations.
25-44 D20.8 Editing multiplier. This number remains 3.5
constant for all iterations in the arc.
45-59 D15.3 Editing RMS. Initial RMS value used for 200.
iteration number 1. Subsequent iterations
use the RMS from the previous iteration.
60-72 D13.1 Electronic bias edit level. Value in cols.
25-44 times value
in cols. 45-59.
73-80 D8.2 Arc convergence criteria. .02
NOTES:
[1] The editing level for each iteration is determined as follows:
Edit level = Edit multiplier * Edit RMS
[2] The "ratio to sigma" for each observation is compared to this edit
level and "ratio to sigmas" greater than the edit level are
eliminated from the current iterations solution.
[3] The electronic bias edit level defaults to the same edit level as
described above. (edit multiplier * edit RMS)
JAN 1992
9201.0
ARC SET - Option Cards
EDIT (cont)
NOTES: (continued)
[4] Time periods may be specified only for the highest order
coefficients
[5] Convergence on first iteration
GEODYN II will converge on the first inner iteration if the
RMS on the EDIT card is within 2% of the first iteration RMS
[6] E-bias Edit level
For E-bias editing the E-bias edit level is given by default
as the edit multiplier * RMS from the EDIT card. If the
"electronic bias edit level" from columns 60-72 of the EDIT
card is non zero, then the value from column 60-72 is used as
the edit level (Not the value in column 60-72 times anything else)
IF CARD OMITTED: The default edit level of 700 (3.5*200) is used.
JUNE 1991
9106.0
ARC SET - Option Cards