FANTIM

                                                                                
----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
FANTIM 
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
1-6     A6         FANTIM - Used for time dependent PHANTOM 
                   parameters (option FANTOM)
                                                                                
7       I1         Index specifying the nature of the introduced
                   arc parameters:
                                                                                
                    = 1 Geometric model arc parameters
                    = 2 Force model arc parameters

25-44   D20.8     Epoch time for a time dependent model          YYMMDDHHMMSS. 
                  [NOTE 1]
                                                                                
45-59   D15.3     Start time for a time dependent option. The    YYMMDDHHMMSS.
                  end times are specified on the FANTOM cards.
                                                                                
60-72   D13.1     Space for real information applicable to all 
                  the parameters in the group.
                                                                                
73-80   D8.2      Space for real information applicable to all
                  the parameters in the group
                                                                                
  NOTES:                                                                        

     [1] This time will be considered to be a reference time with respect to
         which linear rates or periodic terms are evaluated.
                                                                                
                                                                                
     [2] Only one FANTIM card per FANTOM parameter group is allowed.
      
IF CARD OMITTED: And times are included on the FANTOM cards, the run will
abnormally terminate.

OCT 1995

9510.0

ARC SET - Option Cards



Patrick Dahiroc
1998-09-10