----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
SIMTYP
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
COLUMNS FORMAT DESCRIPTION DEFAULT VALUE & UNITS
1-6 A6 SIMTYP: Data for the measurement type
described on this card will be generated
for the tracking configuration defined
on the preceding SIMSAT and SIMSTA cards.
[NOTE 1]
12-14 I3 Measurement type. (See Section 5.0 for
discussion on measurement types.
31-45 D15.8 Measurement noise level, for 1st 0
measurement. [NOTE 2]
46-60 D15.8 Measurement noise level, for 2nd 0
measurement. (in case of paired
measurements) [NOTE 2]
61-70 D10.2 Observation time interval Value from S
SIMLIM card.
NOTE [1] : For simulating paired measurement types the user should only
specify the first measurement in the pair i.e. 17 for the
pair 17-18. GEODYN will automatically simulate both. This
convention applies for all measurement types between 17 and 30.
NOTE [2] : For the noise level use the same units as the observations (M or
or M/Sec for metric type, DEG RAD or MAS for angles). For each
observation the noise level will be multiplied by a random number
between -1 and 1.
UNITS: KM =Kilometers; M =Meters ; S =Seconds ; Kg =Kilograms
DEG=Degrees ; RAD=Radians ; AS =Arc seconds; MAS=Milli-arc seconds
IF CARD OMITTED: If simulated data generation (not replacement) is
invoked and this card is missing the run will
terminate
JUNE 1989
8906.0
SIMULATED DATA INPUT CARDS