----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
NORMPT0 120
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
COLUMNS FORMAT DESCRIPTION DEFAULT VALUE & UNITS
1-6 A6 Requests the computation and output onto unit
20 in GEODYN-IIE of metric data normal points
on the last inner iteration of each data
reduction arc during the last global iteration.
7 I1 Indicates whether or not a normal point report 0
should be printed on unit 15 by GEODYN-IIE.
0 - Print a normal point report on unit 15.
1 - Do not print a normal point report.
8 I1 Maximum number of local iterations to perform 5
in editing each pass of data prior to
formation of normal points.
9-10 I2 Maximum number of physical buffers to be used 2
in outputting normal points to unit 20.
11-14 I4 Controls the maximum number of 1000
observations that will be used in
one data block (minimum no. = 11 ,
maximum = 9999, default value = 40
when EMATRX option is used)
15-17 I3 Number of integration steps over which Integration order
interpolation may be simultaneously minus one.
performed. Must be greater than or
equal to integration order minus one.
18-20 I3 Maximum number of physical buffers per input 10
observation block. This number must be greater
than or equal to the value used by the
Tracking Data Formatter.
JUNE 1991
9106.0
GLOBAL SET
NORMPT (cont)
COLUMNS FORMAT DESCRIPTION DEFAULT VALUE & UNITS
21-24 I4 Normal point bin size in seconds. If a None
positive integer is not entered in this field,
normal points will not be generated.
25-44 D20.8 Normal point pass editing multiplier. Residual edit
(See Arc EDIT option for default) multipler.
45-59 D15.3 Normal point pass editing initial RMS. Editing RMS from
(See Arc EDIT option for default) previous Inner Iter.
73-80 D8.2 Normal point pass editing iteration Inner Iteration
convergence criterion. (See Arc EDIT) RMS convergence.
NOTES:
[1] When in normal point generation mode, large numbers of parameters should
not be estimated. This option also overrides columns 11-17 of the
VECOPT card. Observation data to be input for normal point generation
should be processed through the Tracking Data Formatter with the normal
point option exercised in TDF.
Values in columns 11-14 and 15-17 of this card override values in these
same columns on VECOPT option.
See also Arc Set option card NORMPV.
IF CARD OMITTED: Normal points will not be generated.
NOV 1994
9411.0
GLOBAL SET