NORMPT

                                                                                
----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
NORMPT0              120                                                        
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
1-6     A6     Requests the computation and output onto unit                    
               20 in GEODYN-IIE of metric data normal points                    
               on the last inner iteration of each data                         
               reduction arc during the last global iteration.                  
                                                                                
 7      I1     Indicates whether or not a normal point report        0          
               should be printed on unit 15 by GEODYN-IIE.                      
                                                                                
               0 - Print a normal point report on unit 15.                      
               1 - Do not print a normal point report.                          
                                                                                
 8      I1     Maximum number of local iterations to perform         5          
               in editing each pass of data prior to                            
               formation of normal points.                                      
                                                                                
9-10    I2     Maximum number of physical buffers to be used         2          
               in outputting normal points to unit 20.                          
                                                                                
11-14   I4     Controls the maximum number of                      1000         
               observations that will be used in                                
               one data block (minimum no. = 11 ,                               
               maximum = 9999, default value = 40                               
               when EMATRX option is used)                                      
                                                                                
15-17   I3     Number of integration steps over which       Integration order   
               interpolation may be simultaneously              minus one.      
               performed. Must be greater than or                               
               equal to integration order minus one.                            
                                                                                
18-20   I3     Maximum number of physical buffers per input         10          
               observation block. This number must be greater                   
               than or equal to the value used by the                           
               Tracking Data Formatter.
JUNE 1991

9106.0

GLOBAL SET

NORMPT (cont)

                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
21-24   I4     Normal point bin size in seconds. If a               None        
               positive integer is not entered in this field,                   
               normal points will not be generated.                             
                                                                                
25-44  D20.8   Normal point pass editing multiplier.         Residual edit      
               (See Arc EDIT option for default)              multipler.        
                                                                                
45-59  D15.3   Normal point pass editing initial RMS.       Editing RMS from    
               (See Arc EDIT option for default)           previous Inner Iter. 
                                                                                
73-80  D8.2    Normal point pass editing iteration          Inner Iteration     
               convergence criterion. (See Arc EDIT)        RMS convergence.    
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
NOTES:                                                                          
 [1]  When in normal point generation mode, large numbers of parameters should  
      not be estimated.  This option also overrides columns 11-17 of the        
      VECOPT card.  Observation data to be input for normal point generation    
      should be processed through the Tracking Data Formatter with the normal   
      point option exercised in TDF.                                            
                                                                                
      Values in columns 11-14 and 15-17 of this card override values in these   
      same columns on VECOPT option.                                            
                                                                                
      See also Arc Set option card NORMPV.                                      
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
                                                                                
IF CARD OMITTED: Normal points will not be generated.
NOV 1994

9411.0

GLOBAL SET



Patrick Dahiroc
1998-09-10