PARFIL

                                                                                
----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
PARFIL    7375                                                          20000.  
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
1-6     A6     Requests output of measurement partial                           
               derivative file(s) on last inner iteration                       
               of each data reduction arc during first                          
               global iteration.                                                
                                                                                
7       I1     Indicates whether each arc should open a              0          
               new logical unit for output or continue                          
               writing to the same unit as the previous                         
               arc.                                                             
                                                                                
               0 - Concatenate all arcs providing header                        
                   information between each arc.                                
                                                                                
               1 - CLOSE currently open output file at                          
                   end of each arc and increment output                         
                   unit number for start of each new arc.                       
                                                                                
               2 - ENDFILE currently open output file at                        
                   end of each arc. (applies only to IBM                        
                   type operating environment for                               
                   GEODYN-IIE)                                                  
                                                                                
11-12   I2     Indicates logical unit number (NU1) of first          90         
               segment of file. Maximum segment size is                         
               specified in columns 73-80.                                      
               NOTE: 90 .LE. NU1 .LE. 99                                        
                                                                                
               If segment size is exceeded, the currently open                  
               logical unit will be CLOSED, the unit number                     
               will be incremented by one and output will                       
               continue.
JUNE 1986

8606.0

GLOBAL SET

PARFIL (cont)

                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
                                                                                
11-12 cont.    If column 7 contains a one, then the currently                   
               open logical unit will be CLOSEd at the end                      
               of each arc, the unit number will be incremented                 
               by one and output will continue for the next arc.                
                                                                                
               If column 7 contains a two, then the currently                   
               open logical unit will be ENDFILEd at the end                    
               of each arc, the unit number will remain the same,               
               and output will continue for the next arc.                       
                                                                                
13-14   I2     Maximum unit number (NU2) that will be opened     Same as cols.  
               for output of this partial derivative                11-12       
               file.                                                            
               NOTE: NU1 .LE. NU2 .LE. 99                                       
                                                                                
25-44  D20.8   Partial derivative file number to uniquely       E-Matrix Number 
               identify the file.                               or 0. if no EMAT
                                                                                
73-80   F8.1   Number of blocks (of 512 64-bit words)              20000.       
               of disk space requested for each segment of                      
               the measurement partial derivative file.                         
                                                                                
               A good estimate for the total disk space                         
               required for the entire measurement partial                      
               derivative file may be obtained by multiplying                   
               the number of weighted observations by the                       
               number of adjusted parameters and dividing                       
               by 512.                                                          
                                                                                
               If outputing to tape, specification of a very                    
               large number here will prevent incrementing                      
               of unit number unless specified by column 7.                     
                                                                                
IF CARD OMITTED: No measurement partial derivative file will be generated.
JUL 1998

9808.0

GLOBAL SET



Patrick Dahiroc