SIMDAT

                                                                                
----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
SIMDAT 0                                                                        
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
                                                                                
                                                                                
COLUMNS FORMAT         DESCRIPTION                         DEFAULT VALUE & UNITS
                                                                                
1-6     A6        SIMDAT - Requests output of simulated                         
                  data to UNIT 20 on final iteration.                           
                  Actual data replaced with calculated value                    
                  from final iteration. The simulated data is                   
                  in the GEODYN II binary format expected                       
                  by UNIT 40 of IIS.                                            
                                                                                
 8      I1        Simulated data generation indicator.                          
                                                                                
                  =0 Simulated data will be generated by                        
                     replacing real data with computed data.                    
                                                                                
                  =1 Data will be simulated for measurement                     
                     types and times as specified on the                        
                     SIMDAT control cards following this                        
                     SIMDAT card. The SIMDAT control cards                      
                     may be input as a separate file in UNIT17.                 
                                                                                
10      I1        Indicator specifying the input file of the                    
                  SIMDAT control cards.                                         
                                                                                
                  =1 SIMDAT control cards are input on UNIT17                   
                                                                                
                                                                                
                  Please see NOTE [1] below                                     
                                                                                
NOTE [1]: This Option is not yet available for all measurement types.           
          For the time being only range and range rate, altimetry               
          and angle measurement types can be simulated. For paired              
          angle measurement types read the note on the SIMTYP card.             
                                                                                
IF CARD OMITTED: No data will be simulated.
SEPT 1992

9208.0

SIMULATED DATA INPUT CARDS


Patrick Dahiroc
1998-09-10