----+----1----+----2----+----3----+----4----+----5----+----6----+----7----+----8
NRMPNT
----+----0----+----0----+----0----+----0----+----0----+----0----+----0----+----0
COLUMNS FORMAT DESCRIPTION DEFAULT VALUE & UNITS
1-6 A6 NRMPNT - is used when normal point data
is being processed to designate the minimum
spacing between accepted data for specific
station and/or measurement type. All data closer
than minimum spacing (col 51-60) will be discarded.
Default value on MAXOBS card will be used if
no specific NRMPNT card is in for station or
type
7-14 I8 Station number - The minimum spacing in columns
51-60 will be used for all data from this
station.
16-17 I2 Measurement type - GEODYN I - the minimum
spacing in columns 51-60 will be used for
all data of this type.
51-60 D10.3 Minimum spacing between data points in seconds.
All data closer than this spacing will be
discarded.
NOTE: One can use as many NRMPNT cards as necessary.
If only the station field is present it refers
to all data from that station. If only the
measurement type field is present then it refers to
all data of that type. If both fields are present
then it refers to only data of that type at that
station. Cards with both fields present will
override cards with only station or only measurement
type fields defined. For this function the order of the
cards does not play any role.
AUG 1988
8805.0
TRACKING DATA FORMATTER INPUT CARDS