7. SIMULATED DATA GENERATION

                                                                                
    A.  General Description                                                     
                                                                                
        1.  Force Model                                                         
                                                                                
            a.  50x50 gravity field                                             
            b.  Drag applied using the Jacchia 71 atmospheric density           
                model                                                           
                                                                                
        2.  Printout control                                                    
                                                                                
            a.  Selected option on print and terminal output                    
            b.  Trajectory file output                                          
                Printout is from ORBTVU                                         
                File output (Unit 30 is recommended) is from ORBFIL             
                                                                                
        3.  General notes                                                       
                                                                                
            a.  This is a simulated data generation capability                  
            b.  Measurement type PCE (position only)                            
            c.  Scheduling information must be provided by the user on          
                unit 17 (see below)                                             
            d.  The data subgroup must be omitted in the simulated data         
                generation mode                                                 
            e.  Do not use a VECOPT card with this option                       
            f.  Simulated data capabilities and normal point generation         
                cannot be part of the same job                                  
                                                                                
   B.  Unit 05 Setup IIS                                                        
                                                                                
***************************************                                         
SIMULATED DATA GENERATION - GLOBAL SECTION                                      
***************************************                                         
I64G2E                                                                          
PRNTVU   21                                                                     
TERMVU  1212212222                                                              
EARTH          50 50         3.986004360D+14  6378137.00      298.257           
EPHEM         200                                                               
ENDGLB                                                                          
***************************************                                         
SIMULATED DATA GENERATION - ARC SECTION                                         
***************************************                                         
REFSYS 111          820120                                                      
SATPAR           8903901       33.8200000000   2113.9000000                     
EPOCH               820120 000 0.00000008201200400 0.00000008201300400 0.0000000
ELEMS120            7713600.000         .00044               65.105             
ELEMS2              356.35               270.00              .000000001         
SIMDAT 1 1                                                                      
ORBTVU                  820120040000.00     820130040000.00  300.0              
ORBFIL  30       8903901820120040000.00     820130040000.00  300.0              
STEP             8903901        30.000                                          
ENDARC                                                                          
/*                                                                              
                                                                                
   C.  Unit 17 Description                                                      
                                                                                
       1.  A blank SIMDAT and a SIMLIM card are mandatory                       
                                                                                
       2.  Each individual configuration (unique measurement type               
           satellites and/or station) must be represented by a group            
           that begins with SIMSAT and ends with ENDCON. (See Vol 3             
           SIMDAT)                                                              
                                                                                
       3.  The simulated observations will be output on unit 20 after           
           the first inner iteration.  This data can be fed back into           
           IIS in a data reduction mode. Do not input to TDF!                   
                                                                                
   D.  Unit 17 Setup IIS                                                        
                                                                                
SIMDAT                                                                          
SIMLIM                        300.0                                             
SIMSAT 8903901                                                                  
SIMTIM                        820120040000.  820130040000.                      
SIMTYP       1                1.0                            300.               
ENDCON                                                                          
SIMSAT 8903901                                                                  
SIMTIM                        820120040000.  820130040000.                      
SIMTYP       2                1.0                            300.               
ENDCON                                                                          
SIMSAT 8903901                                                                  
SIMTIM                        820120040000.  820130040000.                      
SIMTYP       3                1.0                            300.               
ENDCON                                                                          
ENDSIM


Patrick Dahiroc
1998-09-10